White Paper: Power Adapters Design Techniques to Meet the New DoE Level VI Efficiency Standards
Summary
With less than a year left before the US Department of Energy's Level VI energy efficiency regulation becomes mandatory, system-level engineers and specifiers are now focused on testing and qualifying external power supplies from different vendors that meet the upcoming efficiency and no-load input power requirements. With GlobTek's newly released Level VI compliant product line, these tasks can be simplified and expedited allowing manufacturers shorter time to market. GlobTek will continue to invest in research and development to push the boundaries of power supply efficiency and no-load input power consumption to meet and exceed current and future energy efficiency standards.
As a recognized leader in power systems solutions, GlobTek, Inc recently released a new line of energy efficient power supplies that will enable system designers and manufacturers to be in compliance with the global energy efficiency regulations, including the upcoming US Department of Energy's (DoE) Energy Conservation Standards for External Power Supplies (EPS), also commonly known as Level VI efficiency standard. Drawing from decades of experience in the design and manufacturing of switch mode power supplies across broad range of applications from ITE, Medical, Audio to Industrial and Consumer Goods, GlobTek understands the intricacies and nuances of both the mandatory and voluntary energy efficiency requirements within the very dynamic global regulatory environment and offer a comprehensive product line of highly efficient and very low no-load input power consumption switchmode power supplies ranging in power levels from 5 watts up to 250 watts.
On February 10, 2014 the US Department of Energy released its final ruling for the new Energy Conservation Standards for External Power Supplies (EPS). This new regulation is a revision to its EISA 2007 EPS efficiency standards.
Mandatory compliance will begin on February 10, 2016 for all covered external power supplies that are manufactured in or imported into the United States. The new standard tightened the prescribed minimum average efficiency of external power supplies during active mode and the maximum input power consumption allowed during no-load mode. It will affect a wide variety of external power supplies used in a wide variety of consumer applications. Compliance with the new regulation is designated by marking roman numeral VI on the product nameplate, packaging or accompanying documentation.
Compared to the current Level V regulation, the new DOE Level VI standard not only has more stringent limits for both power supply average efficiency and noload input power consumption, it also expanded the range of products it covers to include multiple output voltage power supplies and supplies with power level above 250 watts.
Not all external power supplies are covered by the standard. Devices that require Federal Food and Drug Administration (FDA) listing and approval as a medical device and any AC-DC external power supplies with output voltage less than 3 volts and with output current greater than or equal to 1,000 milliamps that are used to charge the battery of a product that is fully or primarily motor operated are not covered. Also, certain external power supplies used for certain life safety and security equipment do not need to meet the no-load mode requirement.
Single-Voltage External AC-DC Power Supply, Basic Voltage | ||
---|---|---|
Nameplate Output Power (Pout) | Minimum Average Efficiency in Active Mode (expressed as a decimal) | Max. Power in No Load Mode (W) |
Pout ≤ 1W | ≥ 0.5 x Pout + 0.16 | ≤ 0.100 |
1W < Pout ≤ 49W | ≥ 0.071 x ln(Pout)-0.0014 x Pout + 0.67 | ≤ 0.100 |
49W < Pout ≤ 250W | ≥ 0.880 | ≤ 0.210 |
Pout > 250W | ≥ 0.875 | ≤ 0.500 |
Single-Voltage External AC-DC Power Supply, Low Voltage | ||
Pout ≤ 1W | ≥ 0.517 x Pout + 0.087 | ≤ 0.100 |
1W < Pout ≤ 49W | ≥ 0.0834 x ln(Pout)-0.0014 x Pout + 0.609 | ≤ 0.100 |
49W < Pout ≤ 250W | ≥ 0.870 | ≤ 0.210 |
Pout > 250W | ≥ 0.875 | ≤ 0.500 |
Single-Voltage External AC-AC Power Supply, Basic Voltage | ||
Pout ≤ 1W | ≥ 0.5 x Pout + 0.16 | ≤ 0.210 |
1W < Pout ≤ 49W | ≥ 0.071 x ln(Pout)-0.0014 x Pout + 0.67 | ≤ 0.210 |
49W < Pout ≤ 250W | ≥ 0.880 | ≤ 0.210 |
Pout > 250W | ≥ 0.875 | ≤ 0.210 |
Single-Voltage External AC-AC Power Supply, Low Voltage | ||
Pout ≤ 1W | ≥ 0.517 x Pout + 0.087 | ≤ 0.210 |
1W < Pout ≤ 49W | ≥ 0.0834 x ln(Pout)-0.0014 x Pout + 0.609 | ≤ 0.210 |
49W < Pout ≤ 250W | ≥ 0.870 | ≤ 0.210 |
Pout > 250W | ≥ 0.875 | ≤ 0.500 |
Multiple-Voltage External Power Supply | ||
Pout ≤ 1W | ≥ 0.497 x Pout + 0.067 | ≤ 0.300 |
1W < Pout ≤ 49W | ≥ 0.075 x ln(Pout) + 0.561 | ≤ 0.300 |
Pout > 49W | ≥ 0.860 | ≤ 0.300 |
Table I. Energy Conservation Standards for Direct Operation EPSs (Copied from US DoE, 10 CFR Part 430 document) |
Emerging Design Techniques to Meet the New Level VI Requirements
The challenges design engineers face in meeting the new and tougher Level VI efficiency and no-load input power requirements is that traditionally, switch mode power supplies tend to be very efficient only when operating at or near its maximum power rating. The efficiency curve is not flat across the entire load range. Older designed power supplies are far less efficient when running below their rated maximum load. This is partly because of the fix losses in the power supply circuitry that becomes dominant as the output load decreases.
With the very stringent average efficiency and no-load input power requirements, incremental design changes or minor adjustments to an existing design such as using better quality components or using a shorter length and bigger gauge output cable to minimize losses due to the wire voltage drop are no longer sufficient to meet the new requirements. Addressing the new Level VI regulation require significant changes in the design at every level, starting from the selection of power train topology, the operating control techniques to implement, secondary side rectification technique, to the selection of the controller ICs and other critical power components. Also, optimization of the auxiliary circuits that traditionally get minimal design attention when it comes to improving efficiency and no-load power consumption like for example the snubber circuits, controller ICs and feedback circuit operating and standby power consumptions, resistive preload, safety capacitor discharge resistors and start-up circuits are now being looked at closely and optimized for minimum losses.
One of the emerging technique implemented in the industry today to meet and exceed tougher energy efficiency requirements is to effectively combine the best power train topology that inherently offers higher efficiency for a given power level, careful component selection and changes in component materials, best design methodology and multi-mode control strategy.
Very high efficiency and very low no-load power consumption can be achieved if the power supply control strategy has multiple operating modes that can seamlessly transition back and forth between modes depending on the amount of load drawn by the end system. Each operating mode is optimized for maximum efficiency and low no-load input power for a given load range. This way, the overall efficiency profile of the power supply becomes relatively flat across much of the load range.
GT-83083 is a 5W series and is available with North American, Australian, China, European and UK AC input blade style while GT-83084 is a 10W series and is available with North American, European and China AC input blade style. Output voltage for both models is 5V, suitable for USB type applications.
For high power range, two desktop models are available. The 180W GTM3057 and 250W GTMF3058 series of AC/DC power supply with built-in power factor correction circuit. Output voltage can be factory set anywhere from 12V to 56V and load current capability of up to 18A. Options in the output cable style, length, connector type is also available. Both of these models are also approved and certified for Medical applications.
All models listed above have full features including tightly regulated output voltage, built-in overcurrent, short circuit, overvoltage and over temperature protections. It also has a very low earth leakage current, common mode noise and low output voltage ripple. For complete list of features, technical specifications, approvals, certificates, connector options and more, click the link provided.
http://en.globtek.com/power-supply-selector/?Efficiency__c=VI
Although most global energy efficiency regulations to date exclude external power supplies used in medical applications, GlobTek's Level VI product line are designed with the same level of quality and attention to details as those power supplies designed and used for medical applications. Some of GlobTek's Level VI power supply line up also carry Medical approvals.
![GlobTek logo](/images/globtek_logo.png)
- US Department of Energy, 10 CFR Part 430, Energy Conservation Program, Energy Conservation Standards for External Power Supplies, Final Rule, April, 11, 2014
- Various online resources related to power supply energy efficiency topics