GT-41062-1805-T3 18 Watt Family of ITE desktop power supplies with 5V output
Description / Features / Specifications:
GT-41062-1805-T3 ITE grade model represents GlobTek’s 18 Watt desktop series of AC/DC adapters with interchangeable cords. These converters are ideally suited to provide reliable power globally, as it features both, Universal 100-240V input at 47-63 Hz and user-changeable power cords (also available from GlobTek). This unit features Regulated outputs with built-in overcurrent, short circuit, overvoltage and thermal protection, as well as low leakage, low ripple, and high efficiency. GlobTek’s GT-41062-1805-T3 series of enclosed power supplies are housed in Impact resistant non-vented Polycarbonate Thermal Conduction-Cooled Cases.INPUT PLUG CONFIGURATION: | EC 60320/C14, 3 PRONGS POWER INLET, CLASS I TYPE |
---|---|
OUTPUT CORD: | 1 CONDUCTOR + SHIELD, 18 AWG STRANDED WIRE, ROUND # 1185, COLOR BLACK, LENGTH (L) OF CORD: 1000 +100, -0 mm. with MOLDED INLINE FERRITE. |
OUTPUT CONNECTOR: | STANDARD, RIGHT ANGLE FEMALE BARREL 5.5 x 2.5 x 11 mm WITH CENTER POSITIVE |
OUTPUT VOLTAGE: | 5 VDC, NO LOAD TO FULL LOAD, NO MINIMUM LOAD REQUIRED |
OUTPUT CURRENT: | 3.6 A |
OUTPUT POWER (RATED): | 18 WATTS MAX |
OUTPUT REGULATION: | +/- 5% MEASURED AT THE OUTPUT CONNECTOR |
LINE VOLTAGE REGULATION: | +/- 1% TYPICAL MEASURED AT FULL LOAD |
OUTPUT RIPPLE (PEAK TO PEAK): | 1% OR 150 mV WHICHEVER IS GREATER. MEASURED AT 20 MHz BANDWIDTH WITH 0.1 μf CERAMIC CAPACITOR IN PARALLEL WITH 10 μf ELECTROLYTIC CAP CONNECTED AT THE END OF OUTPUT CONNECTOR AT NOMINAL LINE |
TURN-ON/TURN-OFF OVERSHOOT: | 5% MAXIMUM, 1mS TYPICAL RECOVERY TIME FOR 25% STEP LOAD |
TURN-ON DELAY: | 1 SECOND, TYPICAL |
HOLD-UP TIME: | 8mS TYPICAL AT NOMINAL INPUT VOLTAGE AND FULL LOAD |
INRUSH CURRENT: | 30A TYPICAL AT 115Vac INPUT AND 60A TYPICAL AT 230Vac INPUT |
SWITCHING FREQUENCY: | 65 KHz TYPICAL |
PROTECTION: | |
OVER-VOLTAGE: | PROTECTED WITH ZENER CLAMP ACROSS OUTPUT |
SHORT CIRCUIT: | PROTECTED, UNIT WILL RECOVER UPON REMOVAL OF FAULT |
INPUT PROTECTION: | INPUT LINE FUSING |
SAFETY: | |
DIELECTRIC WITHSTAND VOLTAGE: | 4242Vdc FROM PRIMARY TO SECONDARY |
EARTH LEAKAGE CURRENT: | < 3.5 mA at 240Vac INPUT VOLTAGE |
OTHER: | |
MTBF: | 200,000 HOURS AT 25°C AMBIENT TEMPERATURE |
OPERATING TEMPERATURE: | 0°C TO 40°C AMBIENT TEMPERATURE |
HUMIDITY: | 0% TO 90% RELATIVE HUMIDITY |
STORAGE TEMPERATURE: | -40°C TO 80°C |
ROHS: | COMPLIES WITH EU 2002/95/EC AND CHINA SJ/T 11363-2006 |
Certifications / Approvals / Safety Compliance:
- UL60950-1, CUL TO 22.2#60950-1, SIQ MARK TO 60950-1
- CCC TO GB4943-2001, GB9254-1998, GB17625.1-2003
- CE CLASS I, AS/NZ 60950, PSE TO J60950, CB REPORT TO 60950-1 2ND EDITION
- IRAM (ARGENTINA) TO EN60950
- EMI: COMPLIES WITH EN55022 CLASS B AND FCC PART 15 CLASS B, VCCI WHEN TESTED WITH RESITIVE LOAD, BOTH CONDUCTED AND RADIATED EMI
- CE MARK: TESTED TO COMPLY WITH EN61000-3-2 EN610003-3 AND EN50082-1 INCLUDING EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
- C-TICK TESTED TO COMPLY WITH AUSTRALIA SECTION 182 OF THE RADIO COMMUNICATION ACT OF 1992.