GTM91120-30VV-F Open Frame/Internal Medical Power Supply

GTM91120-30VV-F
GTM91120-30VV-F, Medical Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, 5-PIN PC BOARD 3.96 mm WAFER CONNECTOR, JVE P/N: 24W1180-05S10-01T-3.6-R2A-CG01 or EQUIVALENT, Output Rating: 30 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: UKCA; RCM; ETL 62368; LPS 62368; CB EN/IEC 60335-1; CB 60601-1; CB 60950; CE; CE; China RoHS; cULus; FCC; GOST-R; Level V; RoHS; SIQ; Designed to meet EN 60601-1; SIQ; Ukraine; VCCI; WEEE; cRUus; IEC/EN60601-1; IEC/EN60950-1; IEC 60335; CE; ETL; CB 60335;RCM;GTM91120-30VV-F, Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, 5-PIN PC BOARD 3.96 mm WAFER CONNECTOR, JVE P/N: 24W1180-05S10-01T-3.6-R2A-CG01 or EQUIVALENT, Output Rating: 30 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: UKCA; RCM; ETL 62368; LPS 62368; CB EN/IEC 60335-1; CB 60601-1; CB 60950; CE; CE; China RoHS; cULus; FCC; GOST-R; Level V; RoHS; SIQ; Designed to meet EN 60601-1; SIQ; Ukraine; VCCI; WEEE; cRUus; IEC/EN60601-1; IEC/EN60950-1; IEC 60335; CE; ETL; CB 60335;RCM;
Information
Model NumberGTM91120-30VV-F
Agency Documentshttp://www.globtek.info/certs/GTM91120-T2%20-T3A%20-FW/
CE EC-Declaration for Medicalhttps://cs.globtek.info/ec_declaration?id=a0Oa000000FysLkEAJ
CE EC-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ec_declaration?id=a0Oa000000FysLkEAJ
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://cs.globtek.info/ukca_declaration?id=a0Oa000000FysLkEAJ
UKCA-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ukca_declaration?id=a0Oa000000FysLkEAJ
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000FysLkEAJ
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000FysLkEAJ
Prop 65 Statementhttps://www.globtek.com/r2/PH7CNf
REACH Declarationhttps://www.globtek.com/r2/eM2co8
Conflict Minerals Declarationhttps://www.globtek.com/r2/vZY8R5
Model Parameters
TypeOpen Frame/Internal
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryMedical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)30
Output Voltage Range (V)5-48
EfficiencyV
Ingress Protection
Size (mm)101.6x50.8x22.30
Enclosure           User-added image

IMPORTANT INSTALLATION NOTES:
FOR PROPER  INSULATION AND GROUNDING RELIABILITY, FOLLOW EITHER OPTIONS BELOW

 
OPTION 1: USE NYLON 4-40 SCREWS AND  NYLON STAND-OFF FOR ALL MOUNTING  HOLES  AND ADD JUMPER 
                    WIRE OPTION SHOWN BELOW FOR  EARTH CONNECTION BETWEEN MOUNTING HOLES 2  AND 4.
  User-added image          RING TERMINAL, AMP P/N: 8-34142-5 AWG 18 STRANDED WIRE,
                                                            GREEN, 130+20,-0 mm LENGTH
 
OPTION 2. USE METALLIC 4-40 SCREWS AND METALLIC STAND-OFF  FOR HOLES 2 AND 4 AND USE NYLON 4-40  
                   SCREWS AND NYLON STAND-OFF FOR HOLES 1 AND 3.   
                   OPTION 2 IS ONLY  APPLICABLE IF SYSTEM CHASSIS, WHERE THE POWER SUPPLY IS MOUNTED IS MADE
                   OUT OF METAL.
 
Rating Table
Model Number (Final ordering #/Part No to be defined)Output NumberVoltageAmps (Convection)Amps (Forced Air)Watts (Convection)Watts (Forced Air)RFQ
* (Final ordering #/Part No to be defined)
Specifications
  1. ELECTRICAL SPECIFICATIONS:
    1. Input Voltage: 100-240 Vac
    2. Input Current: 1.5 A RMS max
    3. Input Frequency: 47 - 63 Hz
    4. Output power (rated): 30Watts max
    Note: Refer to Power Supply information on page 2 for the corresponding rated output power for the specific output voltage.
    5. Output Regulation: +/- 5% measured at the output connector
    6. Line Voltage Regulation: +/- 2% typical measured at full load
    7. Output Ripple (Vp-p): +/-2% maximum, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line
    Optional low ripple option available (RFP4579)
    8. Turn-ON/OFF Overshoot: 5% maximum, 500uS typical recovery time for 25% to 50% step load
    9. Turn-ON Delay: 3 Seconds, maximum @ full load, nominal line
    10. Hold-Up Time: 8mS typical @ nominal input voltage and full load
    11. Inrush Current: 60A maximum cold start @ 240Vac input
    12. Switching Frequency: 100 KHz typical

    B) PROTECTION
    1. Over-Voltage: Protected with a Zener diode clamp across the output
    2. Short Circuit: Hiccup with auto recovery
    3. Over-load: Hiccup with auto recovery
    4. Input Protection: Input line and neutral fusing

    C) SAFETY

    1. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
    2. Warning to service personnel "CAUTION: Double pole/neutral fusing".  This marking is required only for both F1 and F2 installed
    3. Earth Leakage Current: <100 uA at 240Vac input voltage
    4. MTBF: 200,000 hours @ 25°C ambient temperature
    5. Operating Temperature: 0°C to 40°C ambient temperature

    D) OTHER:
    1. MTBF: 200,000 Hours @ 25°C ambient temperature
    2. Humidity: 0% to 90% relative humidity
    3. Storage Temperature: -10°C to 80°C
    4. Cooling: Convection
Derating Curve
Qty (ea.)/Carton50
Individual Box/Gift Box Size (mm)117*82*58
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)442 x 330 x 275
Gross Weight (kg)15.7
Label Width (mm)15.0
Label Height (mm)21.0
Input Configuration
Description5-PIN PC BOARD 3.96 mm WAFER CONNECTOR, JVE P/N: 24W1180-05S10-01T-3.6-R2A-CG01 or EQUIVALENT
User-added image




Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
Request Info