GT-81088-06VV-x.x-W2E Wall Plug-in ICT/ITE Power Supply
GT-81088-06VV-x.x-W2E | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GT-81088-06VV-x.x-W2E, ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, European CEE 7/16 configuration:EN 50075 Europlug 2 PIN, Output Rating: 6 Watts, Power rating with convection cooling (W) , 5-12V in 0.1V increments, Approvals: VCCI; Level V; CE; China RoHS; WEEE; Double Insulation; Ukraine; EAC; RoHS; | ||||||||||||||||||||||||||
Information | ||||||||||||||||||||||||||
Model Number | GT-81088-06VV-x.x-W2E | |||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GT-81088/ | |||||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | |||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0O30000008UldqEAC | |||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | |||||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | |||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0O30000008UldqEAC | |||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | |||||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0O30000008UldqEAC | |||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0O30000008UldqEAC | |||||||||||||||||||||||||
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf | |||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/r2/eM2co8 | |||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 | |||||||||||||||||||||||||
Model Parameters | ||||||||||||||||||||||||||
Type | Wall Plug-in | |||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | |||||||||||||||||||||||||
Category | ICT/ITE Power Supply | |||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | |||||||||||||||||||||||||
Max Input Current (A) | 0.2 | |||||||||||||||||||||||||
Max Output Power Rating (W) | 6 | |||||||||||||||||||||||||
Output Voltage Range (V) | 5-12 | |||||||||||||||||||||||||
Efficiency | V | |||||||||||||||||||||||||
Ingress Protection | ||||||||||||||||||||||||||
Size (mm) | 66*41*25 | |||||||||||||||||||||||||
Enclosure | ||||||||||||||||||||||||||
Rating Table | ||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | ||||||||||||||||||||||||||
Specifications | ||||||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS: 1. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 3. Output Power (Rated): 5 Watts max 4. Output Regulation: +/- 5% for main output, measured at the output connector 5. Line Regulation: +/- 2% Max at full load 6. Output Ripple (Vp-p): 100 mV P-P Max at 20 MHz and output parallel with 0.1uf and 10uf capacitors to ground temperature at 25°C, at 115/230 Vac input voltage 7. Turn-On/Turn-Off Overshoot: 5% maximum, 500 uS max recovery time for 25% step load 8. Turn-On Delay: <2 second 9. Hold-Up Time: 5 mS min at nominal input voltage & full load 10. Switching Frequency: 65 KHz typical 11. No load power consumption: complies with Energy Star and EISA, efficiency Level IV(North America) B) PROTECTION 1. Over-Voltage: Electronically Protection: protected, unit will recover upon removal of fault 2. Over current/Short Circuit: Protected, unit will recover upon removal of fault 3. Other Protection: Input line fusing 4. Dielectric withstand voltage: 4242 Vdc primary-secondary, 2121 Vdc primary-ground C) SAFETY 1. Dielectric Withstand Voltage: 4242Vdc from primary to secondary 2. Touch Current: <0.25mA @ 240Vac input voltage D) OTHER: 1. MTBF: 200,000 hours @ 25°C ambient temperature 2. Operating Temperature: 0°C to 40°C ambient temperature 3. Humidity: 0% to 90% relative humidity 4. Storage Temperature: 20°C to 85°C 5. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006 E) ENCLOSURE 1. Upper Housing: High impact plastic, 94V0 polycarbonate, non-vented 2. Lower Housing: High impact plastic, 94V0 polycarbonate, non-vented 3. Size: 66*34*25 +/-1.0mm | ||||||||||||||||||||||||||
Derating Curve | ||||||||||||||||||||||||||
Qty (ea.)/Carton | 120 | |||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 85*51*75 | |||||||||||||||||||||||||
Individual Box/Gift Box Color | White | |||||||||||||||||||||||||
Master Carton Size (mm) | 445 x 326 x 335 | |||||||||||||||||||||||||
Gross Weight (kg) | ||||||||||||||||||||||||||
Label Width (mm) | 15.7 | |||||||||||||||||||||||||
Label Height (mm) | 23.7 | |||||||||||||||||||||||||
Input Configuration | ||||||||||||||||||||||||||
Description | European CEE 7/16 configuration:EN 50075 Europlug 2 PINThe prongs of the Europlug are 19 mm long. They consist of a 9 mm long conductive tip of 4 mm diameter with a rounded ending, followed by a 10 mm long flexible insulated shaft of not more than 3.8 mm diameter. The two prongs are not exactly parallel and converge slightly; their centres are 19 mm apart at the tip and 18.6 mm apart at the base. The elasticity of the converging prongs provides sufficient contact force for the Europlug's current rating with a variety of socket-hole arrangements. The entire plug is 35.3 mm wide and 13.7 mm high, and must not exceed these dimensions within 18 mm behind its front plane (this allows for the recesses on many European socket types). The left and right side of the plug are formed by surfaces that are at 45° relative to the horizontal plan. | |||||||||||||||||||||||||
Output Configuration | ||||||||||||||||||||||||||
Common output connector options: Click to add to your request.
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions. | ||||||||||||||||||||||||||
Approvals | ||||||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | ||||||||||||||||||||||||||
|