GT-86120-WWVV-X.X-W2A Wall Plug-in ICT/ITE Power Supply
GT-86120-WWVV-X.X-W2A | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GT-86120-WWVV-X.X-W2A, ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V ̴ , 50/60Hz, Australian AS 3112 configuration: SAA 2 pins Class II, Output Rating: 12 Watts, Power rating with convection cooling (W) , 4.2V-12VV in 0.1V increments, Approvals: AS/NZS; WEEE; LPS 62368; Ukraine; RoHS; LPS 60950; Level VI; Double Insulation; China RoHS; CB 62368; CB 60950; Conforms to 62368-1; RCM; | |||||||||||||||||||||||||||||||||
Information | |||||||||||||||||||||||||||||||||
Model Number | GT-86120-WWVV-X.X-W2A | ||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GT-86120-WWVV-W2Z/ | ||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0Oa000000OjT5tEAF | ||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0Oa000000OjT5tEAF | ||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000OjT5tEAF | ||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000OjT5tEAF | ||||||||||||||||||||||||||||||||
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf | ||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/r2/eM2co8 | ||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 | ||||||||||||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||||||||||||
Type | Wall Plug-in | ||||||||||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | ||||||||||||||||||||||||||||||||
Category | ICT/ITE Power Supply | ||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V ̴ , 50/60Hz | ||||||||||||||||||||||||||||||||
Max Input Current (A) | 0.5A | ||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 12 | ||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 4.2V-12V | ||||||||||||||||||||||||||||||||
Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 | ||||||||||||||||||||||||||||||||
Ingress Protection | IPX0 | ||||||||||||||||||||||||||||||||
Size (mm) | 69*42.4*49.5 | ||||||||||||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||||||||||||
3D File Download | https://www.globtek.com/file/dl/gt-86120-wwvv-x_x-w2a_asm.stp | ||||||||||||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||||||||||||
Specifications | |||||||||||||||||||||||||||||||||
ELECTRICAL SPECIFICATIONS: 01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 03. Output Regulation: +/- 5% 04. Ripple and Noise (Vp-p): 100 mVp-p maximum, At 20 MHz, and output parallel with 0.1uF & 47uF capacitors to ground. Temperature at 25 °C, and nominal input voltage 05. Efficiency: Compliant with Efficiency Level VI and ErP European Commission's Ecodesign Directive (2005/32/EC) / CoC Tier 2 Compliant 06. No Load Standby Power: <0.075W @ 230Vac 07. Turn-ON Delay: 3 Seconds maximum at nominal input voltage 08. Rise Time: 100mS maximum at nominal input voltage B) PROTECTION 01. Over-Voltage: 10VDC maximum 02. Over current protection: 4A maximum with auto-recovery function 03. Short Circuit: Short circuit protection is to be included in the construction of the adaptor. The adaptor is designed to withstand continuous current of a short circuit on the output. The adaptor will be short circuit tolerant for an indefinite period. C) SAFETY 01. Dielectric Withstand Voltage: 3000VAC 10mA 1minute or 4242VDC 10mA 1minute from primary to secondary 02. Leakage current: 0.25mA maximum, at nominal AC input voltage and frequency 03. Static Discharge Immunity of 4kV Contact Discharge, 8kV air discharge. D) EMC 01. Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4 Conducted Emissions: Class B, FCC Part 15, Class B Radiated Emissions: Class B, FCC Part 15, Class B 02. Line Frequency Harmonics EN61000-3-2, Class A 03. Voltage Fluctuations/Flicker EN61000-3-3 04. Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2 Static Discharge Immunity EN61000-4-2, 4kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m 80-1000MHz, 80% 1KHz AM. EFT/Burst Immunity EN61000-4-4, 1kV/100kHz. Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM Power Frequency Magnetic Field Immunity EN61000-4-8, 1A/m Voltage Dip Immunity EN61000-4-11, Criteria E) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 50°C ambient temperature (RFP7139) 03. Humidity: 5% to 90% relative humidity 04. Storage Temperature: -20°C to 60°C 05. Cooling: natural convection cooling 06. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006 F) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Markings: Label and/or Pad Printed and/or Molded in the case | |||||||||||||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 120 | ||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 90*54*76 | ||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||||||||||||
Master Carton Size (mm) | 470 x 345 x 340 | ||||||||||||||||||||||||||||||||
Gross Weight (kg) | 15.6 | ||||||||||||||||||||||||||||||||
Label Width (mm) | 39.7 | ||||||||||||||||||||||||||||||||
Label Height (mm) | 16.2 | ||||||||||||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||||||||||||
Description | Australian AS 3112 configuration: SAA 2 pins Class II Used in Australia, New Zealand, Fiji, Papua New Guinea and Tokelau, has two flat pins forming an inverted V-shape. These flat blades measure 6.3 by 1.5 mm with the Active and Neutral pins of 17 mm in length set 30° to the vertical on a nominal pitch of 13.7 mm. A standard power outlet in Australia provides a nominal voltage of 230 volts at a maximum of 10 amps and always includes an earth connection. As in the UK, its outlets are individually switched for extra safety. Argentina uses a similar plug, with pins 1 mm longer.
| ||||||||||||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||||||||||||
Common output connector options: Click to add to your request.
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions. | |||||||||||||||||||||||||||||||||
Approvals | |||||||||||||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||||||||||||
|