GTM961200P120VV.V-TP(SR with fixed Plug 2 pin) |
---|
| GTM961200P120VV.V-TP(SR with fixed Plug 2 pin), ICT/ITE Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, See "Blade/Cord Installed" section. Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths., Output Rating: 120 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: CB 62368; Morocco; PSE; VCCI; PSE; PSE; CE; WEEE; Ukraine; RoHS; Level VI; China RoHS; cETLus; cETLus 60601-1-11; EAC; S-Mark 62368; UKCA; Conforms to 62368-1; |
---|
Information |
---|
Model Number | GTM961200P120VV.V-TP(SR with fixed Plug 2 pin) |
---|
Agency Documents | http://www.globtek.info/certs/GTM961200P/ |
---|
CE EC-Declaration for Medical | https://cs.globtek.info/ec_declaration?id=a0O3a00000M6b8TEAR |
---|
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0O3a00000M6b8TEAR |
---|
CE EC-Declaration for Household | Contact GlobTek for more information |
---|
UKCA-Declaration for Medical | https://cs.globtek.info/ukca_declaration?id=a0O3a00000M6b8TEAR |
---|
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0O3a00000M6b8TEAR |
---|
UKCA-Declaration for Household | Contact GlobTek for more information |
---|
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0O3a00000M6b8TEAR |
---|
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0O3a00000M6b8TEAR |
---|
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf |
---|
REACH Declaration | https://www.globtek.com/r2/eM2co8 |
---|
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 |
---|
Model Parameters |
---|
Type | Desktop/External |
---|
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor |
---|
Category | ICT/ITE Power Supply |
---|
Input Voltage Range (V) | 100-240V~, 50-60 Hz |
---|
Max Input Current (A) | 1.5A |
---|
Max Output Power Rating (W) | 120 |
---|
Output Voltage Range (V) | 12-54 |
---|
Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 |
---|
Ingress Protection | IP42 |
---|
Size (mm) | 149.30*62.80*34.0 |
---|
Enclosure |
|
---|
3D File Download | https://www.globtek.com/file/dl/GTM961200P120VV.V-TP_SR_with_fixed_Plug_2_pin.zip |
---|
Rating Table |
---|
Model Number (Final ordering #/Part No to be defined) | Output Number | Voltage | Amps (Convection) | Amps (Forced Air) | Watts (Convection) | Watts (Forced Air) | RFQ |
---|
* (Final ordering #/Part No to be defined) |
Specifications |
---|
InputInput Voltage: | Specified: 90-264VAC, Nameplate: 100-240VAC 100% rated load current for 90-264VAC 90% rated load current for 85-264VAC 100% rated load current for 90-370VDC |
---|
Input Frequency: | Specified: 47-63Hz, Nameplate: 50-60Hz |
---|
Power Factor: | 0.90 min. @ 230VAC, 0.97 min. @ 115VAC |
---|
No Load Input Power: | < 150mW @ 115/230VAC |
---|
Inrush Current: | < 65A @ 115VAC, < 130A @ 230VAC (cold start) |
---|
Efficiency: | DoE Level VI and EU CoC Tier 2 compliant |
---|
OutputTurn-on Delay: | 1 second typ. |
---|
Output Regulation: | ± 4% (measured at output connector) |
---|
Line Regulation: | ± 0.5% typ. (measured at output connector, full load) |
---|
Ripple: | 1% or 200mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector) |
---|
Startup Overshoot: | 5% max. |
---|
Transient Response: | 5% max. deviation, 1ms typ. recovery time (with 25% to 50% load step) |
---|
Hold-up Time: | 20ms min. |
---|
Power Indicator: | Green LED |
---|
Switching Frequency: | Variable, 25KHz - 125KHz, depending on load |
---|
ProtectionsInput Protection: | 300VAC MOV transient suppressor, input line fusing |
---|
Over-Current Protection | Current limited to less than < 170W / Vout(nom.) and < 13A, auto-restart |
---|
Short-Circuit Protection: | Auto-restart |
---|
Over-Voltage Protection: | 110 - 135% (60V max for models rated 45 - 54V), full load condition, latched off, cycle AC to reset |
---|
Over-Temperature Protection | Internal ambient NTC temperature sensor, latched off, cycle AC to reset |
---|
EnvironmentalMTBF: | 1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3) |
---|
Operating Temperature: | -10°C to 40°C (full load) |
---|
Storage Temperature: | -30°C to 80°C |
---|
Humidity: | 0% to 95% relative humidity, non-condensing |
---|
Altitude: | 5000m |
---|
Cooling: | Convection |
---|
RoHS: | Complies with EU 2011/65/EU and China SJ/T 11363-2006 |
---|
Note 1: | Regarding operating temperature a. See below de-rating table for output power capability at alternate temperature b. Extended low-end temperature range available as a custom option |
---|
SafetyDielectric Withstand Voltage: | 4000VAC or 5656VDC from input to output 3000VAC or 4242VDC from input to earth (Class I models only) |
---|
Touch Current: | Class I: 20µA max. Class II: 70µA max. |
---|
Earth Leakage Current | Class I: 300µA max. Class II: N/A |
---|
Means of Protection: | 2 x MOPP |
---|
Output Isolation Options: | Class I: C6 or C14 inlet (output negative tied to Earth contact) Class II: C8 or C18 inlet Class II FE: C6 or C14 inlet (output isolated from Earth contact) Review isolation options by reading our white paper PSU Isolation and Identity. |
---|
Primary-to-Secondary Bridging Capacitors: | Two IEC60384-14 Class Y1 capacitors |
---|
Earth Continuity Test: | < 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only) |
---|
Compliant Standards: | See listing at end of this datasheet for specific standards |
---|
EMCApplicable Standards: | Medical: EN60601-1-2, 4th edition Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22 Immunity: EN55024, EN61000-6-1, EN61000-6-2 |
---|
Conducted Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
---|
Radiated Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
---|
Harmonic Current Voltage Distortion: | EN61000-3-2, Class A |
---|
Voltage Fluctuations/Flicker: | EN61000-3-3 |
---|
Electrostatic Discharge (ESD) Immunity: | EN61000-4-2, 10KV contact discharge, 18KV air discharge |
---|
Radiated RF Immunity: | EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM |
---|
EFT/Burst Immunity: | EN61000-4-4, 4KV/100kHz. |
---|
Line Surge Immunity: | EN61000-4-5, 2KV differential, 4KV common-mode |
---|
Conducted RF Immunity: | EN61000-4-6, 3VRMS, 80% 1KHz AM |
---|
Power Frequency Magnetic Field Immunity: | EN61000-4-8, 3A/m |
---|
Voltage Dip Immunity: | EN61000-4-11 |
---|
EnclosureHousing: | High impact plastic, 94V0 polycarbonate, non-vented |
---|
Size: | 149.4 * 62.6 * 33.5mm, ± 1.0mm |
---|
AC Input Mechanical Options: | C6, C8, C14, or C18 IEC inlet |
---|
Markings: | Label and/or pad printed and/or laser-etched into case |
---|
Special Options- Reduced leakage current to meet IEC60601-1 Type-CF limits
- Improved EN61000-4-5 line surge immunity (3KV differential, 5KV common-mode)
- Reduced harmonic current levels for LED lighting (EN61000-3-2 Class C) for 85 - 120W load
- Short term output surge capability for motors or other high peak current loads
- Ruggedized construction with improved shock and vibration resistance
- Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
- Custom cordsets, special cordage and connector types
- Custom housing markings
- Custom housing/cordage colors
- Tightened output voltage tolerance
- Reduced output ripple level
- Reduced output power rating
- Low temperature option, down to -40°C
- Epoxy potted version "P2" or "P3" suffix, with flying wires or custom cables
- "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
- Improved ingress protection (IP) rating
Output Connectors |
Derating Curve | |
---|
Qty (ea.)/Carton | 60 |
---|
Individual Box/Gift Box Size (mm) | 158*78*65 |
---|
Individual Box/Gift Box Color | White |
---|
Master Carton Size (mm) | 490 x 410 x 300 |
---|
Gross Weight (kg) | 15.2 |
---|
Label Width (mm) | 79.5 |
---|
Label Height (mm) | 39.5 |
---|
Input Configuration |
---|
Description | See "Blade/Cord Installed" section. Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths.
|
---|
Output Configuration |
---|
Common output connector options: Click to add to your request.
|
|
|
|
|
| L Type (Coaxial 5.5x2.5mm plug) | C Type (Coaxial 5.5x2.1mm plug) | K Type (Coaxial 3.5x1.3mm plug) | LL Type (5.5x2.5mm Locking 760k type) | CL Type (5.5x2.1mm Locking S761k type) | Magnetic Connector |
|
|
|
|
| YL3 Type (KPPX-3P) | YL4 Type (KPPX-4P) | EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) | MSB Type (Micro USB) | Inquire for custom design |
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions. |
Approvals |
---|
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. |
Logo | Description |
---|
Medical 4th Ed. | EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info) | | Indoor Use Only - Mark is on the label or Molded in the case | Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1 | Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1 | | Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration | | UKCA Certification | | WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case | | Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/ | | Ukraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf) |
| Serial Number Information | | CHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf | RoHS | Specifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf | | JAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: https://www.globtek.com/r2/Szj4Vb | No Logo Applicable | CB for IEC 62368-1:2014 (Second Edition) | | Japan: Voluntary Control Council for Interference (VCCI) | Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1 | Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1 | | JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: https://www.globtek.com/r2/Szj4Vb | | JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: https://www.globtek.com/r2/Szj4Vb | | Test standard: EN 55032: 2012+AC: 2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015 | Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1 | Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1 | | Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe) | | S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/) |
|