GTM965500P-WWWVV-XX |
---|
| GTM965500P-WWWVV-XX, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 550 Watts, Power rating with convection cooling (W) 300, 12-54V in 0.1V increments, Approvals: Conforms to 62368-1; Morocco; UKCA; |
---|
Information |
---|
Model Number | GTM965500P-WWWVV-XX |
---|
CE EC-Declaration for Medical | https://cs.globtek.info/ec_declaration?id=a0O3a00000MNu7HEAT |
---|
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0O3a00000MNu7HEAT |
---|
CE EC-Declaration for Household | Contact GlobTek for more information |
---|
UKCA-Declaration for Medical | https://cs.globtek.info/ukca_declaration?id=a0O3a00000MNu7HEAT |
---|
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0O3a00000MNu7HEAT |
---|
UKCA-Declaration for Household | Contact GlobTek for more information |
---|
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0O3a00000MNu7HEAT |
---|
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0O3a00000MNu7HEAT |
---|
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf |
---|
REACH Declaration | https://www.globtek.com/r2/eM2co8 |
---|
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 |
---|
Model Parameters |
---|
Type | Open Frame/Internal |
---|
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor |
---|
Category | ICT / ITE / Medical Power Supply |
---|
Input Voltage Range (V) | 100-240V~, 50-60 Hz |
---|
Max Input Current (A) | 6.5A |
---|
Max Output Power Rating (W) | 550 |
---|
Output Voltage Range (V) | 12-54 |
---|
Efficiency | |
---|
Ingress Protection | N/A |
---|
Size (mm) | 127.0 (L) x 76.2 (W) x 34.3 (H) |
---|
Enclosure |
|
---|
Rating Table |
---|
Model Number (Final ordering #/Part No to be defined) | Output Number | Voltage | Amps (Convection) | Amps (Forced Air) | Watts (Convection) | Watts (Forced Air) | RFQ |
---|
* (Final ordering #/Part No to be defined) |
Specifications |
---|
Features- High power density 3" x 5" format
- Full power rating at 50°C ambient and 90VAC
- Auxiliary +12V fan and +5V standby outputs
- Power-good, remote-off, & remote-sense
- Output voltage fine adjustment
- 20ms min. holdup time for full power range
- Available with earthed output or floating output (with functional earth)
- ITE/ICT and medical (2 x MOPP) certified
InputInput Voltage: | 90 - 264VAC (Nameplate: 100 - 240VAC) |
---|
Input Frequency: | 47 - 63Hz (Nameplate: 50 - 60Hz) |
---|
Input Current: | 6.5A max. @ 100VAC, 5.2A typ. @ 115VAC, 2.5A typ. @ 240VAC (full load) |
---|
No Load Input Power: | < 500mW, 240VAC |
---|
Inrush Current: | < 35A @ 115VAC , < 70A @ 240VAC (cold start @ 25°C) |
---|
Efficiency: | 92 - 95% typ. |
---|
Power Factor: | > 0.95 @ 115Vac, > 0.90 @ 240VAC (full load) |
---|
Main OutputTotal Output Power (Main + Standby + Fan Output): | 550W (with forced air cooling) 300W (natural convection cooling) |
---|
Turn-on Delay: | < 2 seconds @ 115VAC |
---|
Output Voltage Regulation: | ± 2.5% (set point tolerance + load/line regulation, measured at output connector) |
---|
Load Regulation: | ± 1.0% (measured at output connector) |
---|
Line Regulation: | ± 0.5% (measured at output connector) |
---|
Ripple: | < 1% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW) |
---|
Transient Response: | ± 5% deviation max. (with 50% load step), recovery to within ±1% within 1ms |
---|
Startup Overshoot: | < 5% |
---|
Hold-up Time: | 20ms min. (100VAC, full load) |
---|
Power-Good (PG): | Signal typically goes low ~10ms ahead of AC power failure or entering of protection state 5V logic level, VH = 4.90V typ. @ IPG= 100µA |
---|
Remote-Off (RO): | Pull 'Remote Off' to COM to disable main output; leave floating or connect to +5VSB otherwise IRO = 2mA typ. during disabled/off state |
---|
Remote-Sense: | Up to 500mV total cable-drop compensation, reverse and short circuit protected |
---|
Output Voltage Fine Adjustment: | Via potentiometer, ±5% adjustment range |
---|
Standby OutputOutput Voltage: | 5V |
---|
Output Current: | 1A |
---|
Output Voltage Regulation: | ± 5.0% (set point tolerance + load/line/cross regulation) |
---|
Ripple: | 2% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW) |
---|
Hold-Up Time: | 20ms min. |
---|
Always On? | Yes |
---|
Fan OutputOutput Voltage: | 12V |
---|
Output Current: | 0.5A |
---|
Output Voltage Regulation: | ± 15.0% (set point tolerance + load/line/cross regulation) |
---|
Ripple: | 1% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW) |
---|
Always On? | Follows 'Remote-Off' signal (i.e. Fan is off when RO is pulled low.) |
---|
ProtectionsInput Protection: | MOV transient suppressor, dual high breaking capacity fuses |
---|
Over-Voltage Protection: | 110-150%, latching, cycle AC power to reset |
---|
Over-Current Protection: | 105-150%, non-latching with auto-recovery |
---|
Short Circuit Protection: | Non-latching with auto-recovery |
---|
Over-Temperature Protection: | Latching, cycle AC power to reset |
---|
EnvironmentalMTBF: | 1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3) |
---|
Operating Temperature: | -20°C to 50°C (full output power), -20°C to 70°C (with derating) |
---|
Storage Temperature: | -40°C to 85°C |
---|
Humidity: | 0% to 95% relative humidity, non-condensing |
---|
Altitude: | 5000m max. |
---|
Vibration: | Conforms to EN60068-2-6 |
---|
SafetyCertifications: | IEC60601-1 IEC62368-1 IEC60335-1 |
---|
Dielectric Withstand Voltage: | 4000VAC (primary-to-secondary) 1500VAC (primary-to-earth) 1500VAC (secondary-to-earth) [Functional earth option only] |
---|
Output Touch Current: | NC: <100µA SFC: <500µA |
---|
Earth Leakage Current: | NC: <200µA SFC: <1.0mA |
---|
Means of Protection: | 2 x MOPP (primary-to-secondary) 1 x MOPP (primary-to-earth) 1 x MOPP (secondary-to-earth) [Functional earth option only] |
---|
EMCCertifications: | IEC60601-1-2 EN55032 (CISPR32) EN55035 (CISPR35) |
---|
Conducted Emissions: | Class B, FCC Part 15 (with resistive load) |
---|
Radiated Emissions: | Class B, FCC Part 15 (with resistive load) |
---|
Harmonic Current Voltage Distortion: | EN61000-3-2, Class A |
---|
Voltage Fluctuations/Flicker: | EN61000-3-3 |
---|
Electrostatic Discharge (ESD) Immunity: | EN61000-4-2, 10KV contact discharge, 20KV air discharge (applied to input, output, or control connector) |
---|
Radiated RF Immunity: | EN61000-4-3, 10V/m 80-2700MHz, 80% 1KHz AM. |
---|
EFT/Burst Immunity: | EN61000-4-4, 4KV/100kHz. |
---|
Line Surge Immunity: | EN61000-4-5, 2KV differential-mode, 4KV common-mode |
---|
Conducted RF Immunity: | EN61000-4-6, 3VRMS, 80% 1KHz AM |
---|
Power Frequency Magnetic Field Immunity: | EN61000-4-8, 30A/m |
---|
Voltage Dip Immunity: | EN61000-4-11 |
---|
MechanicalDimensions (nom.) Open-Frame (GTM965500P): | 127.0 x 76.2 x 33.4mm (5.00" x 3.00" x 1.31") [Height measurement is PCB thickness + tallest component] |
---|
Dimensions (nom.) Open-Frame with baseplate (GTM965500P-BP): | 127.0 x 76.2 x 39.1mm (5.00" x 3.00" x 1.54") |
---|
Dimensions (nom.) Enclosed with top fan (GTM965500P-TF): | 138.0 x 88.0 x 57.4mm (5.43" x 3.47" x 2.26") |
---|
Dimensions (nom.) Enclosed with end fan (GTM965500P-EF/-EFI): | 161.0 x 88.0 x 43.0mm (6.34" x 3.47" x 1.69") |
---|
Fan Audible Noise: Enclosed with top fan (GTM965500P-TF): | 28.5dBA typ. |
---|
Fan Audible Noise: Enclosed with end fan (GTM965500P-EF/-EFI): | 27.5dBA typ. |
---|
Mounting to end-application enclosure: | Refer to the mechanical drawing for the maximum/recommended penetration depths of mounting screws used to secure the power supply to the end-application enclosure. Failure to adhere to the specified depths may pose a safety risk. |
---|
Input/Output Connectors
Input Connector for Open-Frame, -BP, and -TF (J1): | Connector on PCB: JST B3P5-VH Recommended mate: JST VHR-5N Pinout: 1: Neutral | 2: Line | 3: Earth |
---|
Input Connector for -EF: | Connector on enclosure: TE/AMP 350767-1 Recommended mate: TE/AMP 350766-1 Pinout: 1: Line | 2: Neutral | 3: Earth |
---|
Input Connector for -EFI: | Connector on enclosure: IEC60320 C14 inlet Recommended mate: IEC60320 C13 power cord |
---|
Main Output Connectors for -M4 Suffix (J2A, J2B): | Connector on PCB: M4 PCB terminal Recommended mate: M4 or #8 ring terminal (brass or copper) Recommended mounting torque: 1.2Nm Pinout: J2A: V+ | J2B: V- |
---|
Main Output Connector for -CN Suffix [≤24A only] (J2): | Connector on PCB: Molex 0039288080 Recommended mate: Molex 0039012085 Pinout: 1, 2, 5, 6: V+ | 3, 4, 7, 8: V- |
---|
Standby Output + Signal Connector (J3): | Connector on PCB: Amphenol 98414-G06-06LF Recommended mate: Amphenol 10073599-006LF Pinout: A01: Remote Off | A02: SNS+ | A03: SNS- | B01: Power Good | B02: COM | B03: +5VSB |
---|
Fan Output Connector (J4): | Connector on PCB: Molex 22-04-1021 Recommended mate: Molex 22-01-1022 Pinout: 1: +FAN | 2: -FAN |
---|
Negative/common connection: | V- (J2) and COM (J3) are separated by 2.2Ω to prevent main output current from returning through J3. V- and COM may be connected together at the end-system PCB. |
---|
Earth connection: | Connect four M3 mounting holes to earth. (Mounting to a metal plate is recommended)
Connect pin 3 of J1 to earth.
Care must be taken to ensure adequate creepage/clearance to earth. Check relevant safety standards for specific requirements. Note: Heatsinks are live and not connected to earth.
When the end-system enclosure is non-conductive, using the baseplate (-BP) or enclosed versions (-TF, -EF) is recommended as a convenient way to connect all four holes to earth. |
---|
|
Derating Curve |
|
---|
Qty (ea.)/Carton | |
---|
Individual Box/Gift Box Size (mm) | |
---|
Individual Box/Gift Box Color | |
---|
Master Carton Size (mm) | TBD |
---|
Gross Weight (kg) | |
---|
Label Width (mm) | TBD |
---|
Label Height (mm) | TBD |
---|
Input Configuration |
---|
Description | null |
---|
Approvals |
---|
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. |
Logo | Description |
---|
Medical 4th Ed. | EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info) | Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1 | Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1 | | Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/ | | UKCA Certification | Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1 | Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1 | | Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/ | | UKCA Certification |
|